Fan convector for efficient heating/cooling
Even Heating or Cooling
Low Sound level
Choose between simple or sophisticated control
For wall or ceiling
Simple installation and easy maintenance minimises installation costs and the risk of faults.
PCW is suitable for boosting the heat distribution from a heat pump or a district heating system.
The air movement created by PCW balances the temperature difference between the floor and ceiling, gives higher efficiency and lower energy consumption compared to radiators without a fan.
Our many controls enable everything from simple three-step manual control to fully automatic operation, change-over control to switch between heating and cooling, and weekly programmes. Up to 10 convectors can be controlled by a single controller.
PCW is a flexible solution where the convector can be used for heating or cooling.
PCW can be installed on the wall or ceiling and is intended for permanent installation. Water connection made on left side of the unit. Fan convectors with connections on the right hand side are available to order.
Fan convector PCW is available in two versions:
PCWxx2S, 2 pipe system, 3 row coil for heating or cooling. Also available with supplementary electric coil.
PCWxx4S, 4 pipe system, 3 row coil for cooling and single row coil for heating
Equipped with:
adjustable exhaust grilles to be able to spread the air in two different directions
a centrifugal fan that gives an even and continuous air flow across the whole water coil, which optimises the heat supply
washable filter in polypropylene, easy to install and remove
drip tray, for collecting condensation water during cooling operation, is premounted on the convector. Drip trays for valves are available as accessories
Recommended level controls for PCW
Control options for manual control
For 2 or 4 pipe system (PCR1 or PCEB):
Manual control of fan in 3 steps
Manual selection of heating or cooling
Manual selection of the thermostat control: only heating or both fan and heating
Possibility of an external control signal for switching between heating and cooling. (Only PCEB)
Option to install a sensor (PCT). Low temperature. (Only PCEB)
Complete control equipment:
Integrated control
PCR1, control panel
PCVRxxx, valve kit
External control
PCEB, control panel
PCVRxxx, valve kit
Control options for automatic control
For 2 or 4 pipe systems (PCR2, PCEC or PCEAN):
Manual or automatic control of fan in 3 steps
Manual or automatic selection of heating or cooling
Option of thermostat control with automatic speed control and ON/OFF control of valve(s)
Option to install a sensor (PCT). Low temperature
Option of change-over control for 2 pipe systems (requires T2 probe accessories)
Option of week programme (only PCEAN)
Complete control equipment:
Integrated control
PCR2, control panel
PCVRxxx, valve kit
External control
PCEC/PCEAN, control panel
PCPU, power board
PCVRxxx, valve kit
External control for up to 10 units
PCEC/PCEAN, control panel (1 pc)
PCPU, power unit for each unit
PCVRxxx, valve kit. 1 per PCW for 2-pipe system, 2 per PCW for 4-pipe system
When installing 4-pipe systems, valves for heating and cooling are needed and a cold and hot water circuit must be available.